Trusted Microwave Test Benches for Modern Engineering Laboratories

Precision-built RF and microwave laboratory systems backed by 20+ years of engineering expertise, OEM manufacturing, and dependable technical support.

Institutions
0 +
Years of Experience
0 +
Products
0 +
Industries Served
0 +

Trusted by leading institutions across India  IISc · IIT · BEL · DRDO · Manipal · M.S. Ramaiah · BMSCE · RVCE and many more..

Product Overview

Technilab Microwave Test Benches are complete laboratory systems designed to help students, educators, and researchers understand microwave engineering through practical experimentation.

Each system integrates carefully selected RF and microwave components into a structured learning platform, enabling users to perform experiments across microwave generation, transmission, measurement, wave propagation, antenna characteristics, and passive microwave devices.

tl 003

Every test bench is manufactured to deliver consistent performance, ease of operation, and long-term reliability, making it suitable for both academic laboratories and advanced research environments.

microwave source (c band)

Why Choose Our Microwave Test Benches

Complete Lab Solution

Industry-Standard Experiments

OEM Manufactured

Technical & After-Sales Support

KLYSTRON POWER SUPPLY

technilab klystron

Overview

The Technilab Klystron Power Supply provides regulated beam, repeller, and heater voltages required for Reflex Klystron operation. Built-in square wave and sawtooth modulation enable accurate microwave experiments, making it an essential component of microwave laboratory test benches.

KLYSTRON POWER SUPPLY SPECIFICATION
Model TLKPS-204
Beam Supply
Voltage Range 200 – 450 V Continuously Variable
Current 50mA Max
Regulation Better Than 0.5% for ±10% variation in mains Supply Voltage
Ripple Less than 5mV rms
Repeller Supply
Voltage Range -10V to -270V DC continuously Variable
Regulation 0.25% for ±10% variation
Heater Supply 6.3V DC (regulated)
Modulation
Square Wave Freq.: 500 Hz-2000Hz Max. Amp. + 110 Volt peak to peak Amplitude and frequency continuously variable
Sawtooth Freq.: 50Hz – 150Hz Amplitude – 60 V Max: peak to peak Amplitude and frequency continuously variable
Operation Voltage 230 V ± 10%, 50 Hz. A.C.

GUNN POWER SUPPLY

technilab gunn ps

Model : TLGS-205

Overview

Provides a stable and regulated DC supply for Gunn Oscillator operation, ensuring consistent microwave signal generation for RF and microwave laboratory experiments.

GUNN POWER SUPPLY SPECIFICATION
Voltage Range 0 to 12 Volts Variable
Current 1 Amp. Max
Regulation 0.2% for ± 10% variation in the Mains Supply Voltage
Ripple 1M V rms
Modulation Frequency 1KHz ± 10% (900-1100Hz)
Output Connector BNC (F) for Gunn Oscillator & TNC (F) for Pin Modulator

VOLTAGE STANDING WAVE RATION (VSWR) METERS

technilab gunn ps

Overview

A precision measurement instrument used to detect and measure standing wave patterns, enabling accurate analysis of microwave power, impedance matching, and transmission characteristics.

Specifications of VSWR, Meter Model : TLSW 214
Sensitivity 0.2µ V at a 200 Ohms input impedance for full scale deflection.
Noise Level At least 5 dB below full scale at rated sensitivity and maximum band width With input terminated in 100 ohms and 500 ohms for crystal low and high respectively.
Calibration Square law, meter indicates SWR, dB.
Range 70 db, Input attenuator provides 60dB in 10 dB steps, accuracy ± 0.2 dB per 10 dB steps Maximum Cummulative error ± 0.5dB.
Scales Selector “Normal”, “Expand” and -5 dB Frequency
Meter Scale SWR1-4, SWR 3-10, expand SWR 1 1-3, dB 0-10, expand dB 0-2
Gain Control Adjusts the reference level, variable range 0-10 db approx.
Input “Bolo” bias provided for 4.3 mA low current bolo meters. “Crystal” 200 ohms for low impedance crystal rectifier & 200 K ohms high impedance crystal rectifier as null detector
Recorder Output Socket provided for recording having 1 V for full scale deflection. Internal resistance of 1000 ohms or less
A/C Output BNC Connector for amplified output.
Input Connector BNC (F)
Frequency 1000Hz ± 10%
Power 230 volts A.C. ± 10%, 50 Hz, mains supply.
Specifications of VSWR, Meter Model : TLSW 215
Sensitivity 0.2µ V for full scale deflection at maximum bandwidth on low impedance crystal input.
Noise Level At least 5 dB below full scale at rated sensitivity and maximum band width With input terminated in 100 ohms or 500 ohms for crystal low and high respectively.
Range 70 db, in 10 dB and 2 dB steps.
Range Accuracy 0.1 dB per 10dB steps
Input Unbiased low and high impedance crystal, biased crystal (200Ω 200K) Low and high current bolometers (4.5 & 8.7 mA) (200 ohm)
Meter Scale SWR1-4, SWR 3-10, expand SWR 1 1-3, dB 0-10, expand dB 0-2
Gain Control Adjusts the reference level, variable range 0-10 db approx.
Input “Bolo” bias provided for 4.3 mA low current bolo meters. “Crystal” 200 ohms for low impedance crystal rectifier & 200 K ohms high impedance crystal rectifier as null detector
Input Frequency 1 KHz adjustable ± 10% by front panel control.
Band Width Variable 25 Hz to 110 Hz.
Meter Scale SWR1-4, SWR 3-10, expand SWR 1 1-3, dB 0-10, expand dB 0-2
Gain Control Adjusts the reference level, variable range 0-10 db approx.
Recorder Output 0-1V DC, output connector, Banana Socket.
Amplifier output 0-0.3 Vrms into atleast 10K ohms, output connector BNC (F)
Input Connector BNC (F)
Power 230 volts A.C. ± 10%, 50 Hz, mains supply.

Model No TL 001 Microwave Test bench X BAND : FREQUENCY : 8.2 TO 12.4 GHz EXPERIMENTS

tl 001

Overview

An entry-level X-Band microwave laboratory system designed for fundamental RF and microwave experiments, making it ideal for introductory engineering laboratories.

Specifications
Sl.No Microwave Signal Source – VCO Based QTY
1 Microwave Signal Source – VCO Based 1
2 R F Power Meter 1
3 Micro strip Resonator 1
4 Micro Strip Power Divider 1
5 Micro strip Branch line coupler 1
6 Micro strip Paraller line coupler 1
7 RF Detector 1
8 SMA Matched Termination 100
9 SMA – BNC Cable 1
10 SMA – SMA RF Cable (RG 188) – 1 meter 100
11 SMA – SMA RF Cable Short Length 1
12 6 dB Attenuator 2

Model No TL 002 Microwave Test bench (Microwave Trainer Kit – GUNN DIODE Source Based)

technilab gunn diode based

Overview

A comprehensive microwave trainer kit featuring a Gunn Diode source, designed for practical learning of microwave generation, transmission, and measurement techniques.

Specifications
Sl.No Gunn Power Supply Power Supply – Solid State QTY
1 Gunn Oscillator 1
2 Pin Modulator 1
3 Isolator 1
4 Detector Mount 1
5 Direct Reading Frequency Meter 1
6 Variable Attenuator 1
7 Slotted Section 1
8 Tunable Probe 1
9 Screws And Nuts 100
10 Cooling Fan 1
11 BNC – BNC Cable 2
12 Waveguide Stand 2
13 Matched Termination 1
14 VSWR Meter 1
15 Shorting Plate 1
16 VSWR Meter 2
17 Variable Attenuator 1
18 VSWR MeteTNC – TNC Cable 2

Model No TL 003 Microwave Test bench (Microwave Trainer Kit – Klystron Source Based)

tl 003

Overview

A Klystron-based microwave laboratory system that enables detailed study of microwave engineering principles through a wide range of practical experiments.

Specifications
Sl.No Gunn Power Supply Power Supply – Solid State QTY
1 Gunn Oscillator 1
2 Pin Modulator 1
3 Isolator 1
4 Detector Mount 1
5 Direct Reading Frequency Meter 1
6 Variable Attenuator 1
7 Slotted Section 1
8 Tunable Probe 1
9 Screws And Nuts 100
10 Cooling Fan 1
11 BNC – BNC Cable 2
12 Waveguide Stand 2
13 Matched Termination 1
14 VSWR Meter 1
15 Shorting Plate 1
16 VSWR Meter 2
17 Variable Attenuator 1
18 VSWR MeteTNC – TNC Cable 2

Model No TL 004 Microwave Test bench (Microwave Trainer Kit – Klystron Source Based) X Band : Frequency Range : 8.2 to 12.4 Ghz Power output > 25 mW

tl 003

Overview

An advanced X-Band microwave training system with enhanced experiment capabilities, delivering reliable performance for engineering education and research applications

Specifications
Model TLKPS-204
Beam Supply
Voltage Range 200 – 450 V Continuously Variable
Current 50mA Max
Regulation Better Than 0.5% for ±10% variation in mains Supply Voltage
Ripple Less than 5mV rms
Repeller Supply
Voltage Range -10V to -270V DC continuously Variable
Regulation 0.25% for ±10% variation
Heater Supply 6.3V DC (regulated)

Model No TL 005 Microwave Test bench (Microwave Trainer Kit – Klystron Source Based) X Band : Frequency Range : 8.2 to 12.4 Ghz Power output > 25 mW

tl 003

Overview

Our most comprehensive microwave laboratory platform, designed for advanced RF experimentation, postgraduate studies, and research laboratories requiring expanded capabilities.

Specifications
Model TLKPS-204
Beam Supply
Voltage Range 200 – 450 V Continuously Variable
Current 50mA Max
Regulation Better Than 0.5% for ±10% variation in mains Supply Voltage
Ripple Less than 5mV rms
Repeller Supply
Voltage Range -10V to -270V DC continuously Variable
Regulation 0.25% for ±10% variation
Heater Supply 6.3V DC (regulated)

Multi-Hole Directional Coupler

1

Overview

A precision waveguide component used to sample microwave power with minimal signal loss, enabling accurate power measurement and signal monitoring.

Specifications
Model Band Freq. Range (GHz) Waveguide O/P Connector Crystal Diode
TL-124 S 2.60 - 3.95 WR-284 BNC(F) IN21

Phase Shifters

2

Designed to introduce controlled phase variations in microwave signals, making them essential for phase measurement and wave propagation experiments.

Specifications
Model Band Freq. Range (GHz) Waveguide O/P Connector Crystal Diode
TL-124 S 2.60 - 3.95 WR-284 BNC(F) IN21
TL-124 C 3.95 - 5.85 WR-229 BNC(F) IN21
TL-124 J 5.85 - 8.20 WR-137 BNC(F) IN23
TL-124 X 8.20 - 12.40 WR-90 BNC(F) IN23
TL-124 Ku 12.40 - 18.00 WR-62 BNC(F) IN23
TL-124 K 18.00 - 26.50 WR-42 BNC(F) IN23

Pin Modulator

3
A microwave modulation device that uses a PIN diode to control signal amplitude, supporting pulse modulation and communication experiments.
Specifications
Model Band Freq. Range (GHz) Waveguide O/P Connector Crystal Diode
TL-124 S 2.60 - 3.95 WR-284 BNC(F) IN21
TL-124 C 3.95 - 5.85 WR-229 BNC(F) IN21
TL-124 J 5.85 - 8.20 WR-137 BNC(F) IN23
TL-124 X 8.20 - 12.40 WR-90 BNC(F) IN23
TL-124 Ku 12.40 - 18.00 WR-62 BNC(F) IN23
TL-124 K 18.00 - 26.50 WR-42 BNC(F) IN23

Slide Screw Tuners

4
Provides precise impedance matching by minimizing reflections within waveguide systems, improving measurement accuracy during microwave experiments.
Specifications
Model Band Freq. Range (GHz) Waveguide O/P Connector Crystal Diode
TL-124 S 2.60 - 3.95 WR-284 BNC(F) IN21
TL-124 C 3.95 - 5.85 WR-229 BNC(F) IN21
TL-124 J 5.85 - 8.20 WR-137 BNC(F) IN23
TL-124 X 8.20 - 12.40 WR-90 BNC(F) IN23
TL-124 Ku 12.40 - 18.00 WR-62 BNC(F) IN23
TL-124 K 18.00 - 26.50 WR-42 BNC(F) IN23

Tunable Probe

6
Used to detect microwave signals within a slotted waveguide, allowing precise measurement of electric field distribution and standing waves.
Specifications
Model Band Freq. Range (GHz) Waveguide O/P Connector Crystal Diode
TL-124 S 2.60 - 3.95 WR-284 BNC(F) IN21
TL-124 C 3.95 - 5.85 WR-229 BNC(F) IN21
TL-124 J 5.85 - 8.20 WR-137 BNC(F) IN23
TL-124 X 8.20 - 12.40 WR-90 BNC(F) IN23
TL-124 Ku 12.40 - 18.00 WR-62 BNC(F) IN23
TL-124 K 18.00 - 26.50 WR-42 BNC(F) IN23

E-H Tuners

4
Waveguide tuning devices used to achieve impedance matching and optimize microwave system performance for laboratory applications.
Specifications
Model Band Freq. Range (GHz) Waveguide O/P Connector Crystal Diode
TL-124 S 2.60 - 3.95 WR-284 BNC(F) IN21
TL-124 C 3.95 - 5.85 WR-229 BNC(F) IN21
TL-124 J 5.85 - 8.20 WR-137 BNC(F) IN23
TL-124 X 8.20 - 12.40 WR-90 BNC(F) IN23
TL-124 Ku 12.40 - 18.00 WR-62 BNC(F) IN23
TL-124 K 18.00 - 26.50 WR-42 BNC(F) IN23

Slotted Section With Probe Carriage

5
A precision waveguide assembly that enables accurate measurement of standing wave patterns, guide wavelength, and impedance characteristics.
Specifications
Model Band Freq. Range (GHz) Waveguide O/P Connector Crystal Diode
TL-124 S 2.60 - 3.95 WR-284 BNC(F) IN21
TL-124 C 3.95 - 5.85 WR-229 BNC(F) IN21
TL-124 J 5.85 - 8.20 WR-137 BNC(F) IN23
TL-124 X 8.20 - 12.40 WR-90 BNC(F) IN23
TL-124 Ku 12.40 - 18.00 WR-62 BNC(F) IN23
TL-124 K 18.00 - 26.50 WR-42 BNC(F) IN23

Twists

7
Waveguide components designed to rotate the plane of electromagnetic wave propagation while maintaining signal integrity throughout the transmission path.
Specifications
Model Band Freq. Range (GHz) Waveguide O/P Connector Crystal Diode
TL-124 S 2.60 - 3.95 WR-284 BNC(F) IN21
TL-124 C 3.95 - 5.85 WR-229 BNC(F) IN21
TL-124 J 5.85 - 8.20 WR-137 BNC(F) IN23
TL-124 X 8.20 - 12.40 WR-90 BNC(F) IN23
TL-124 Ku 12.40 - 18.00 WR-62 BNC(F) IN23
TL-124 K 18.00 - 26.50 WR-42 BNC(F) IN23

Waveguide Passive & Active Components

9
A comprehensive range of precision-manufactured microwave components designed to support signal transmission, measurement, and laboratory experimentation.
Specifications
Model Band Freq. Range (GHz) Waveguide O/P Connector Crystal Diode
TL-124 S 2.60 - 3.95 WR-284 BNC(F) IN21
TL-124 C 3.95 - 5.85 WR-229 BNC(F) IN21
TL-124 J 5.85 - 8.20 WR-137 BNC(F) IN23
TL-124 X 8.20 - 12.40 WR-90 BNC(F) IN23
TL-124 Ku 12.40 - 18.00 WR-62 BNC(F) IN23
TL-124 K 18.00 - 26.50 WR-42 BNC(F) IN23

Waveguide Horn Antennas

8
High-performance antennas designed for microwave transmission and radiation pattern experiments, widely used in antenna and propagation studies.
Specifications
Model Band Freq. Range (GHz) Waveguide O/P Connector Crystal Diode
TL-124 S 2.60 - 3.95 WR-284 BNC(F) IN21
TL-124 C 3.95 - 5.85 WR-229 BNC(F) IN21
TL-124 J 5.85 - 8.20 WR-137 BNC(F) IN23
TL-124 X 8.20 - 12.40 WR-90 BNC(F) IN23
TL-124 Ku 12.40 - 18.00 WR-62 BNC(F) IN23
TL-124 K 18.00 - 26.50 WR-42 BNC(F) IN23

GUNN Oscillator

10

A microwave source that generates stable continuous-wave signals using Gunn diode technology, ideal for practical RF and microwave laboratory applications.

Specifications
Model Band Freq. Range (GHz) Waveguide O/P Connector Crystal Diode
TL-124 S 2.60 - 3.95 WR-284 BNC(F) IN21

Klystron Mount

11

A precision mounting assembly designed to securely house Reflex Klystron Tubes while ensuring efficient microwave signal generation.

Specifications
Model Band Freq. Range (GHz) Waveguide O/P Connector Crystal Diode
TL-124 S 2.60 - 3.95 WR-284 BNC(F) IN21
TL-124 C 3.95 - 5.85 WR-229 BNC(F) IN21
TL-124 J 5.85 - 8.20 WR-137 BNC(F) IN23
TL-124 X 8.20 - 12.40 WR-90 BNC(F) IN23
TL-124 Ku 12.40 - 18.00 WR-62 BNC(F) IN23
TL-124 K 18.00 - 26.50 WR-42 BNC(F) IN23

Liquid/Solid Dielectric Cell

12
Designed for dielectric constant measurements of liquid and solid materials, supporting material characterization experiments in microwave laboratories.
Specifications
Model Band Freq. Range (GHz) Waveguide O/P Connector Crystal Diode
TL-124 S 2.60 - 3.95 WR-284 BNC(F) IN21
TL-124 C 3.95 - 5.85 WR-229 BNC(F) IN21
TL-124 J 5.85 - 8.20 WR-137 BNC(F) IN23
TL-124 X 8.20 - 12.40 WR-90 BNC(F) IN23
TL-124 Ku 12.40 - 18.00 WR-62 BNC(F) IN23
TL-124 K 18.00 - 26.50 WR-42 BNC(F) IN23

Matched Termination

13

A waveguide termination that absorbs microwave energy with minimal reflections, ensuring accurate experimental measurements.

Specifications
Model Band Freq. Range (GHz) Waveguide O/P Connector Crystal Diode
TL-124 S 2.60 - 3.95 WR-284 BNC(F) IN21
TL-124 C 3.95 - 5.85 WR-229 BNC(F) IN21
TL-124 J 5.85 - 8.20 WR-137 BNC(F) IN23
TL-124 X 8.20 - 12.40 WR-90 BNC(F) IN23
TL-124 Ku 12.40 - 18.00 WR-62 BNC(F) IN23
TL-124 K 18.00 - 26.50 WR-42 BNC(F) IN23

Moveable Short/ Moveable Precision Short

14

Provides adjustable short-circuit termination for standing wave and impedance measurement experiments in microwave systems.

Specifications
Model Band Freq. Range (GHz) Waveguide O/P Connector Crystal Diode
TL-124 S 2.60 - 3.95 WR-284 BNC(F) IN21
TL-124 C 3.95 - 5.85 WR-229 BNC(F) IN21
TL-124 J 5.85 - 8.20 WR-137 BNC(F) IN23
TL-124 X 8.20 - 12.40 WR-90 BNC(F) IN23
TL-124 Ku 12.40 - 18.00 WR-62 BNC(F) IN23
TL-124 K 18.00 - 26.50 WR-42 BNC(F) IN23

Fixed attenuators

16

Precision attenuation devices that provide a constant reduction in microwave power for stable and repeatable experimental conditions.

Specifications
Model Band Freq. Range (GHz) Waveguide O/P Connector Crystal Diode
TL-124 S 2.60 - 3.95 WR-284 BNC(F) IN21
TL-124 C 3.95 - 5.85 WR-229 BNC(F) IN21
TL-124 J 5.85 - 8.20 WR-137 BNC(F) IN23
TL-124 X 8.20 - 12.40 WR-90 BNC(F) IN23
TL-124 Ku 12.40 - 18.00 WR-62 BNC(F) IN23
TL-124 K 18.00 - 26.50 WR-42 BNC(F) IN23

Circulator & Isolator

17

Circulator

Essential microwave components that control signal direction and minimize unwanted reflections, ensuring stable and reliable system performance.

Specifications
Model Band Freq. Range (GHz) Waveguide O/P Connector Crystal Diode
TL-124 S 2.60 - 3.95 WR-284 BNC(F) IN21
TL-124 C 3.95 - 5.85 WR-229 BNC(F) IN21
TL-124 J 5.85 - 8.20 WR-137 BNC(F) IN23
TL-124 X 8.20 - 12.40 WR-90 BNC(F) IN23
TL-124 Ku 12.40 - 18.00 WR-62 BNC(F) IN23
TL-124 K 18.00 - 26.50 WR-42 BNC(F) IN23
18

Isolator

A non-reciprocal microwave device that allows signal transmission in one direction while protecting sensitive equipment from reflected power.

Specifications
Model Band Freq. Range (GHz) Waveguide O/P Connector Crystal Diode
TL-124 S 2.60 - 3.95 WR-284 BNC(F) IN21
TL-124 C 3.95 - 5.85 WR-229 BNC(F) IN21
TL-124 J 5.85 - 8.20 WR-137 BNC(F) IN23
TL-124 X 8.20 - 12.40 WR-90 BNC(F) IN23
TL-124 Ku 12.40 - 18.00 WR-62 BNC(F) IN23
TL-124 K 18.00 - 26.50 WR-42 BNC(F) IN23

Coaxial To Waveguide Adaptors

19

Designed to efficiently transition microwave signals between coaxial cables and waveguide systems with minimal insertion loss.

Specifications
Model Band Freq. Range (GHz) Waveguide O/P Connector Crystal Diode
TL-124 S 2.60 - 3.95 WR-284 BNC(F) IN21
TL-124 C 3.95 - 5.85 WR-229 BNC(F) IN21
TL-124 J 5.85 - 8.20 WR-137 BNC(F) IN23
TL-124 X 8.20 - 12.40 WR-90 BNC(F) IN23
TL-124 Ku 12.40 - 18.00 WR-62 BNC(F) IN23
TL-124 K 18.00 - 26.50 WR-42 BNC(F) IN23

Cross Directional Coupler

20

A specialized directional coupler used for accurate forward and reverse power measurements in microwave transmission systems.

Specifications
Model Band Freq. Range (GHz) Waveguide O/P Connector Crystal Diode
TL-124 S 2.60 - 3.95 WR-284 BNC(F) IN21
TL-124 C 3.95 - 5.85 WR-229 BNC(F) IN21
TL-124 J 5.85 - 8.20 WR-137 BNC(F) IN23
TL-124 X 8.20 - 12.40 WR-90 BNC(F) IN23
TL-124 Ku 12.40 - 18.00 WR-62 BNC(F) IN23
TL-124 K 18.00 - 26.50 WR-42 BNC(F) IN23

Detector Mount

21

Houses the microwave detector diode and converts microwave energy into measurable electrical signals for analysis and experimentation.

Specifications
Model Band Freq. Range (GHz) Waveguide O/P Connector Crystal Diode
TL-124 S 2.60 - 3.95 WR-284 BNC(F) IN21
TL-124 C 3.95 - 5.85 WR-229 BNC(F) IN21
TL-124 J 5.85 - 8.20 WR-137 BNC(F) IN23
TL-124 X 8.20 - 12.40 WR-90 BNC(F) IN23
TL-124 Ku 12.40 - 18.00 WR-62 BNC(F) IN23
TL-124 K 18.00 - 26.50 WR-42 BNC(F) IN23

E & H Plane Bends

22

Waveguide bends engineered to change signal direction while maintaining optimal microwave transmission performance.

Specifications
Model Band Freq. Range (GHz) Waveguide O/P Connector Crystal Diode
TL-124 S 2.60 - 3.95 WR-284 BNC(F) IN21
TL-124 C 3.95 - 5.85 WR-229 BNC(F) IN21
TL-124 J 5.85 - 8.20 WR-137 BNC(F) IN23
TL-124 X 8.20 - 12.40 WR-90 BNC(F) IN23
TL-124 Ku 12.40 - 18.00 WR-62 BNC(F) IN23
TL-124 K 18.00 - 26.50 WR-42 BNC(F) IN23

E-Plane, H-Plane and Magic Tee

23

E-Plane TEE

Precision waveguide junctions used for signal splitting, combining, and microwave network analysis in laboratory experiments.

Specifications
Model Band Freq. Range (GHz) Waveguide Calibration VSWR
TL-125 S 2.60 - 3.95 WR-284 10 1.03
TL-125 C 3.95 - 5.85 WR-229 10 1.03
TL-125 J 5.85 - 8.20 WR-137 10 1.03
TL-125 X 8.20 - 12.40 WR-90 10 1.03
TL-125 Ku 12.40 - 18.00 WR-62 10 1.03
TL-125 K 18.00 - 26.50 WR-42 10 1.03
24

H-Plane TEE

An H-Plane TEE is a waveguide TEE in which the axis of its side arm is shunting the E field or parallel to the H field of the main guide and attaching the another waveguide.

Specifications
Model Band Freq. Range (GHz) Waveguide Calibration VSWR
TL-125 S 2.60 - 3.95 WR-284 10 1.03
TL-125 C 3.95 - 5.85 WR-229 10 1.03
TL-125 J 5.85 - 8.20 WR-137 10 1.03
TL-125 X 8.20 - 12.40 WR-90 10 1.03
TL-125 Ku 12.40 - 18.00 WR-62 10 1.03

Attenuators

15

Used to accurately reduce microwave signal power without significantly affecting signal quality, enabling controlled laboratory measurements.

Specifications
Model Band Freq. Range (GHz) Waveguide O/P Connector Crystal Diode
TL-124 S 2.60 - 3.95 WR-284 BNC(F) IN21
TL-124 C 3.95 - 5.85 WR-229 BNC(F) IN21
TL-124 J 5.85 - 8.20 WR-137 BNC(F) IN23
TL-124 X 8.20 - 12.40 WR-90 BNC(F) IN23
TL-124 Ku 12.40 - 18.00 WR-62 BNC(F) IN23
TL-124 K 18.00 - 26.50 WR-42 BNC(F) IN23

Frequently Asked question

What is a Microwave Test Bench?

A Microwave Test Bench is a complete laboratory system used to study microwave engineering concepts through practical experiments. It includes RF and microwave components such as power supplies, waveguides, attenuators, couplers, and measuring instruments, enabling students and researchers to understand microwave transmission, propagation, and measurement techniques.

Our Microwave Test Benches are designed for engineering colleges, universities, research laboratories, defence organisations, and technical training centres offering RF and microwave engineering education.

Depending on the selected model, users can perform experiments including VSWR measurement, frequency and power measurement, waveguide characteristics, directional coupler analysis, attenuator and phase shifter studies, antenna radiation patterns, circulator and isolator characteristics, dielectric constant measurement, and more.

Gunn Diode-based systems are ideal for continuous-wave microwave experiments and simplified laboratory setups, while Klystron-based systems offer a broader range of microwave experiments and are widely used for advanced engineering education and research applications.

Yes. Technilab offers customised configurations based on your curriculum, laboratory requirements, experiment list, and institutional needs.

Yes. We provide installation guidance, technical assistance, product training, and dependable after-sales support to ensure your laboratory operates efficiently

Our team will recommend the most suitable model based on your course curriculum, laboratory objectives, number of students, and budget.

Yes. In addition to Microwave Test Benches, we supply waveguide components, RF instruments, antenna trainer kits, microwave accessories, and customised laboratory solutions to help institutions build complete RF and microwave laboratories

Looking for the Right Microwave Test Bench?

From undergraduate laboratories to advanced research facilities, Technilab offers reliable microwave training systems tailored to your curriculum and laboratory requirements.

kit tlms 01
logo

Technilab Instrument is a reputed organisation engaged in design, manufacture ,distribute and service provider of Test and Measuring Instruments and RF and microwave components. The company is managed by a team of experienced engineers having vast experience in Instrumentation, Sales and support.